Single-phase 60 Hz variable-frequency power supply
Since joining the WTO, China’s economy has integrated with the global market, creating opportunities for export-oriented electrical equipment manufacturers. Due to the lack of unified grid standards across different countries, the production of export products requires simulating the grid conditions of various nations while ensuring stability. In the past, systems utilizing voltage regulators for voltage adjustment, voltage stabilizers for voltage stabilization, and generators for secondary frequency conversion were widely adopted; however, these methods were gradually replaced by variable-frequency power supplies due to their high power consumption, significant noise levels, and poor stability. The AC60 programmable variable-frequency power supply is specifically designed and manufactured for voltage and frequency transformation testing of imported and exported electrical products. It can provide voltage and frequency outputs conforming to the grid standards of various countries, features digitally adjustable output voltage and frequency without discrete steps, delivers stable and pure waveforms, and effectively eliminates grid interference. This power supply is suitable for voltage and frequency transformation testing of export electrical products, as well as for conducting various precision tests in laboratories, metrology rooms, and other similar environments, or as a power source for 60 Hz equipment.
Get a Quick Quote Whatsapp - Equipped with overvoltage, overcurrent, short-circuit, and overheating warning devices
- Controlled by a 16-bit microprocessor, featuring intelligent functionality and flexible, user-friendly operation.
- Low-distortion interference, fully isolated input/output, safe and reliable
- Unique instantaneous value control: minimal waveform distortion and high control accuracy.
- The dynamic response is extremely fast; when the load varies from 0% to 100%, the steady-state response time is <0.1s.
- Provides standard grid voltage and frequency specifications from around the world for the simulation testing of various electrical products.
- No electromagnetic interference, contains minimal harmonic components, and has undergone special treatment to prevent dry winding;
- Efficiency exceeds 85%; it is suitable for a wide range of loads, including inductive, capacitive, and resistive loads.
- Original imported German Siemens IGBT high-frequency inverter and core components – stable and reliable.
- Output voltage: Low range: 0–150 V; High range: 0–300 V, continuously adjustable
- Multi-functional single device, integrating measurement and display: outputs voltage, current, frequency, and power/power factor readings with a 0.5-class accuracy.
Execution Standards: “GB7260-87 – Uninterruptible Power Supply Equipment”; “Q/01AK001-2005 – Programmable Variable Frequency Voltage Regulation Power Supply”
| Low-power single-phase 60 Hz variable-frequency power supply |
| type | Ay60-11005 | Ay60-1101 | Ay60-1103 | Ay60-1105 | Ay60-31010 |
| capacity | 500VA | 1KVA | 3KVA | 5KVA | 10KVA |
| output Current | low-end | 4.2A | 8.4A | 25A | 42A | 84A |
| top grade | 2.1A | 4.2A | 12A | 21A | 42A |
| input voltage | 220V/380V±10%,50hz |
| Input phase | Single-phase/Three-phase four-wire |
| output voltage | Low range: 0–150 V (continuous adjustment); High range: 0–300 V (continuous adjustment) |
| output frequency | Fixed frequencies: 50 Hz / 60 Hz / 100 Hz / 200 Hz; and continuous adjustable frequency range: 40.0 Hz – 200.0 Hz |
| Load Regulation Rate | ≤±1% |
| frequency stability | Fixed frequency: ≤±0.01%; Variable frequency: ≤±0.1% |
| Three-phase imbalance | Phase: 120° ± 2°; Phase difference <3% of rated value |
| Waveform distortion degree | THD≤2% |
| reaction time | ≤2mS |
| show accuracy | 4-frequency meters | Resolution: 0.1 Hz |
| 4-voltmeter | Resolution: 0.1 V |
| 4-Ammeter | Resolution: 0.01 A |
| 4 Power Meters | Resolution: 0.1W |
| Communication Interface (Optional) | RS232 or RS485 is optional |
| protocol | MODBUS Communication Protocol |
| defencive function | Overvoltage, overcurrent, overheating, overload, short-circuit protection, and automatic alarm system |
| Insulating reactance | 500Vdc 20MΩ |
| Dielectric insulation | 1800 VAC / 5 mA / 1 minute |
| cooling-down method | Forced fan cooling |
| working temperature | -20℃-40℃ |
| relative humidity | 0–90% (non-condensing state) |
| above sea level | 1,500 meters |
| structure | 19-inch rack-mountable | Cabinet dimensions (Width × Depth × Height), mm |
| size | 3U | 5U | 560×350×600 | 660×400×700 |
| High-power single-phase 60 Hz variable-frequency power supply |
| type | Ay60-31015 | Ay60-31020 | Ay60-31030 | Ay60-31045 | Ay60-31060 | Ay60-31100 |
| capacity | 15KVA | 20KVA | 30KVA | 45KVA | 60KVA | 100KVA |
| output Current | low-end | 126A | 168A | 250A | 375A | 500A | 840A |
| top grade | 63A | 84A | 125A | 188A | 250A | 420A |
| input voltage | 380V±10%,50hz |
| Input phase | Three-phase four-wire system |
| output voltage | Low range: 0–150 V (continuous adjustment); High range: 0–300 V (continuous adjustment) |
| output frequency | Fixed frequencies: 50 Hz / 60 Hz / 100 Hz / 200 Hz; and continuous adjustable frequency range: 40.0 Hz – 200.0 Hz |
| Load Regulation Rate | ≤±1% |
| frequency stability | Fixed frequency: ≤±0.01%; Variable frequency: ≤±0.1% |
| Three-phase imbalance | Phase: 120° ± 2°; Phase difference <3% of rated value |
| Waveform distortion degree | THD≤2% |
| reaction time | ≤2mS |
| show accuracy | 4-frequency meters | Resolution: 0.1 Hz |
| 4-voltmeter | Resolution: 0.1 V |
| 4-Ammeter | Resolution: 0.01 A |
| 4 Power Meters | Resolution: 0.1W |
| Communication Interface (Optional) | RS232 or RS485 is optional |
| protocol | MODBUS Communication Protocol |
| defencive function | Overvoltage, overcurrent, overheating, overload, short-circuit protection, and automatic alarm system |
| Insulating reactance | 500Vdc 20MΩ |
| Dielectric insulation | 1800 VAC / 5 mA / 1 minute |
| cooling-down method | Forced fan cooling |
| working temperature | -20℃-40℃ |
| relative humidity | 0–90% (non-condensing state) |
| above sea level | 1,500 meters |
| Dimensions (Width × Depth × Height) mm | 830×450×1100 | 1100×480×1200 |
Aviation Ground Support
Suitable for aircraft ground power systems and aviation maintenance operations.
Onshore Power Supply
Shore power supplies electricity to docked ships from land grids, replacing on-board generators to cut fuel consumption and emissions.
Variable Frequency
Variable frequency power supply outputs adjustable voltage and frequency. It simulates global grid power for testing electrical equipment.
Military & Defense
Applicable to military electronic systems and specialized defense equipment testing.
Start Your Project with a Reliable Partner
Get high-quality products, fast turnaround, and competitive pricing tailored to your business needs.