Hộp tải DC

The AY-DC-R DC load bank is equipped with a pure resistive load module; it can simulate various power loads and meet the full-load testing requirements for generator sets, machine rooms, and other power supply systems, making it an essential testing tool for production workshops, laboratories, installation and commissioning sites, as well as scientific research and development facilities.

Nhận báo giá nhanh WhatsApp

    DC Load Box Product Features:

    • Load characteristics: Resistive loads utilize stainless steel alloy resistors. These stainless steel alloy resistors are custom-designed products developed independently by our company, featuring a low temperature coefficient and low inductance.
    • Resistor Selection: The resistors utilize high-melting-point nickel-chromium wire with a melting point of over 1200 °C; since the design load is only 50% of the material’s rated load, they can operate stably and continuously over an extended period;
    • The load is cooled by forced air cooling using an axial flow fan, enabling continuous long-term operation of the load.
    • The bottom of the cabinet is equipped with universal casters with brakes, while the top of the cabinet is equipped with a load-bearing suspension ring.
    • During load/unload testing, the accuracy is ≤ ±3%, the resistance temperature coefficient is low, the power variation under both cold and hot conditions is minimal, and the accuracy surpasses that of other resistive loads.
    • Load switching method: The system can be controlled via a local manual rotary knob, or the customer’s host computer can switch the load between various power levels.

    DC Load Box Product Protection:

    • Load Protection: Since the load box is required to operate for extended periods, a comprehensive load monitoring and load protection system is extremely important.
    • Thermal Protection: During each test, the operator must first turn on the cooling fan before the system is permitted to perform load increment or decrement operations.
    • Fan fault protection: The system only permits load increment or decrement when the fan is running and operating normally;
    • Overtemperature Protection: When a system fault occurs and causes the load to exceed its temperature limit, the system automatically disconnects the load, thereby providing protection for the load.
    • Emergency Stop Protection: When a load fault or a fault occurs in the tested equipment, pressing the emergency stop switch will halt the test.
    • Short-circuit protection and overcurrent protection: A fuse is installed at the output terminal of the load box; in the event of a system short-circuit fault, the load will be automatically disconnected.
    product nameHộp tải DC
    product modelAY-DC-R
    loadtypeResistive
    bracketResistive load: 1W,2W,5W,10W,20W,… up to 1000 kW; load accuracy error ≤ 3±%
    điện áp định mứcDC 24.28 V, 30 V, 50 V; 100 V, 200 V… up to 1000 V
    Load accuracyResistance: ±3%
    Load Control Method1. Local manual control (manual adjustment of the load box)

    2. Remote automatic control (provides communication ports and communication protocols)

    communication modeEthernet
    Electrical parameter measurementIt can display the load current and voltage for each group locally and upload the data to a host computer.
    Load ProtectionLoad overtemperature protection, fan protection, emergency stop protection, heat dissipation protection, short-circuit protection, and overcurrent protection
    operate modeSuitable for long-duration continuous operation; it can operate continuously when the heat dissipation fan is running.
    Load connection methodCopper busbar lead-out;
    Load cooling methodAxial flow fan with forced air cooling, forward airflow, rear exhaust.
    Altitude used<6,500 meters
    operating ambient temperature-20℃~+55℃
    product sizeCustomizable dimensions according to customer requirements
    Product installation locationindoor
    Total product weightVaries with changes in power level

    dịch vụ hỗ trợ mặt đất hàng không

    Dịch vụ hỗ trợ mặt đất hàng không

    Thích hợp cho các hệ thống cấp điện mặt đất của máy bay và các hoạt động bảo dưỡng hàng không.

    nguồn điện từ bờ

    Hệ thống cấp điện từ bờ

    Hệ thống cấp điện từ bờ cung cấp điện cho các tàu đang neo đậu từ mạng lưới điện trên đất liền, thay thế cho các máy phát điện trên tàu nhằm giảm mức tiêu thụ nhiên liệu và lượng khí thải.

    tần số biến đổi

    Tần số biến đổi

    Bộ nguồn tần số biến đổi cho phép điều chỉnh cả điện áp và tần số. Thiết bị này mô phỏng nguồn điện lưới toàn cầu để kiểm tra các thiết bị điện.

    quân sự và quốc phòng

    Quân sự và Quốc phòng

    Áp dụng cho việc thử nghiệm các hệ thống điện tử quân sự và thiết bị quốc phòng chuyên dụng.

    Hãy bắt đầu dự án của bạn cùng một đối tác đáng tin cậy

    Bắt đầu dự án của bạn cùng một đối tác đáng tin cậy

    Hãy tận hưởng những sản phẩm chất lượng cao, thời gian hoàn thành nhanh chóng và mức giá cạnh tranh, được thiết kế phù hợp với nhu cầu kinh doanh của quý khách.

    Nhận hỗ trợ ngay